VAF Meters. LED, 230V, 96*96, Black Colour.
1 Phase & 3 Phase systems, 11 to 300V AC (L-N), 19 to 519V AC (L-L) measurement, accuracy of ±0.5% for voltage, ±1% for current, ±0.1Hz for frequency, ±0.5% for RPM, and ±1% for run hour.
3 phase LED Voltage Ampere Frequency meter, with Power and Power Factor, 96x96mm, Black Colour.
Compatible for 1 phase 2 wire, 3 phase 3 wire, 3 phase 4 wire systems. Accuracy of ±0.5% for voltage & current, 0.1% for frequency, 0.01% for PF, 1% for power, Class 1 for active, reactive & apparent energy.
LED Energy meter (V, A, P, Q, TH up to 31) with RS 485, 96*96, Black Colour.
Compatible for 1 phase 2 wire, 2 phase 3 wire, 3 phase 4 wire systems. Accuracy of ±0.5% for voltage & current, ±0.1% for frequency, ±0.01% for PF, Class 1 for active, reactive & apparent energy. RS485 Communication MODBUS RTU.
Network analyzer V, A, P, Q, KW, KVAR, TH up to 31), LCD 96*96 White Colour.
Compatible for 1 phase 2 wire, 3 phase 3 wire, 3 phase 4 wire systems. Accuracy of ±0.5% for voltage & current, ±0.1% for frequency, ±0.01% for PF, Class 1 for active, reactive & apparent energy. CE RoHS certified.
Din Rail Network analyzer V, A, P, Q, KW, KVAR, TH up to 31), LCD 96*96 White Colour.
Compatible for 1 phase 2 wire, 2 phase 3 wire, 3 phase 3 wire, 3 phase 4 wire systems. Accuracy of ±0.5% for voltage & current, ±0.1% for frequency, ±0.01% for PF, Class 1 for active, reactive & apparent energy.
Energy Meter, Din Rail, 3-phase up to 100 direct connection 100A, RS485.
Direct current measurement up to 100A, Dual-Input measurement. Compatible with 1 phase 2 wire, 3 phase 3 wire, 3 phase 4 wire systems. RS485 Modbus communication. CE Certified.
Energy Meter, Din Rail, 1-phase up to 100 direct connection 100A, RS485.
Compatible with 1 phase 2 wire system, Self-Supplied. RS485 Modbus communication, Mbus variant available. CE, MID Certified.
Active Energy Meter, LED, 6 Digits 96*96.
Compatible with 1 phase 2 wire, 2 phase 3 wire, 3 phase 4 wire systems. Accuracy of Class 1 for energy. LED Display with 1 row of 6 digits. RS485 and MODBUS RTU communication.
Energy meters, LCD, 8 Digits, RS485, 96*96.
LCD Display with 1 row of 8 digits. Class 1 for Active energy. Pulse output, RS485, and Modbus RTU communication.
LED Ammeter, 1Ø, 48X96mm.
1 phase 2 wire systems. Accuracy of ±0.5% of F.S. 4 digit 7 segment LED display.
LED Ammeter, 1Ø, 96x96mm.
1 phase 2 wire systems. Accuracy of ±0.5% of F.S. 4 digit 7 segment LED display.
LED Ammeter, 3Ø, 96x96mm.
3 Phase 4 Wire, 3 Phase 3 Wire & 1 Phase 2 Wire systems. Accuracy of ±0.5% of F.S. 4 digit 7 segment LED display.
LED Voltmeter, 1Ø, 48X96mm.
1 phase 2 wire systems. Accuracy of ±0.5% of F.S. 3 Digit 7 segment LED display.
LED Voltmeter, 1Ø, 96x96mm.
1 phase 2 wire systems. Accuracy of ±0.5% of F.S. 3 Digit 7 segment LED display.
LED Voltmeter, 3Ø, 96x96mm.
1 phase 2 wire, 3 phase 3 wire, 3 phase 4 wire systems. Accuracy of ±0.5% of F.S. 4 digit 7 segment LED display.
LED Voltmeter, 3Ø, 96x96mm.
1 phase 2 wire, 3 phase 3 wire, 3 phase 4 wire systems. Accuracy of ±0.5% of F.S. 4 digit 7 segment LED display.